Signal generator
The signal generator is needed to transmit test signals and the screen
view from the MSK 33 during "Comfortable Up/Downstream
measurement" (see system description). In addition to an internal test
picture of coloured bars it has an external modulation input
(CVBS/RGB + sound) and is double-sideband modulated.
The channels/frequencies and levels can be selected freely.
Only use the signal generator on free channels so that
programmes and services in the cable network are not
interrupted. Please use the operating concept on page 2 for help
with understanding the operating sequence.
Function Button actuation Display
Switch on unit when depressed
briefly
The upper display appears first,
then the lower display shortly
afterwards with the last function
that was set
On
Off
Select "Signal generator"
main function and
show battery charge state
Confirm selected function
Show last signal level set
Menu
Select
Set signal level
W X
- +
Enter signal level directly
followed by "Enter"
or
0 9
see above
Set transmission frequency
in MHz
W X
+
- +
SignalGenerator..
Accu 100 %
SG Level
XX.X dBµV
SG Frequency
224.25 MHz
KATHREIN MVG10
NG Store
nr: 0
SG Level
60.0 dBµV