Kathrein MVG 10 Stereo Receiver User Manual


 
System description and usage
10
The spectrum at the head-end can be printed out from the MSK 33 (1)
using the print command "Prt 999" on the MVG 10 (1).
The command "Clear" clears the spectrum presentation on the
MSK 33 (1).
Downstream measurement:
The MVG 10 (2) is switched from signal generator mode to
downstream sweep generator mode via the MSK 33 (1) using the
command "Fkt A 1" on the MVG 10 (1).
The MVG 10 (2) sweeps the forward path in the free frequency
ranges.
The MSK33 (2) receives the signals in MVG 10 – tracking mode.
The MVG 10 (2) is switched back to signal generator mode with the
command "Fkt A 0" on the MVG 10 (1). This is performed via the
turn-on voltage of the SCART line.
Uscart = 12 V effects recall no. 1 on MVG 10.
Uscart = 0 V effects recall no. 0 on MVG 10.