Extron electronic DVI DL 201 Rx Stereo Receiver User Manual


 
DVI DL 201 Tx/Rx • Conguration and Operation
3-5
Using pass-through mode with DDC routed to the
remote display
N
This is the factory default setting.
N
Although DDC can be routed to the remote display, there
may be instances when the signals become corrupted or
weak. In those cases, the source device may be unable to
boot up correctly.
1. Set the EDID Minder switch to the off (down)
position and the Remote DDC switch to the
on (up) position (see the gure at right). The
position of the Default EDID switch is not
relevant.
2. Connect the source device to the transmitter
input.
3. Connect the display device to the receiver output and, if
required, the local monitor to the transmitter output.
4. Connect the transmitter to the receiver with the three
twisted pair cables.
Transmitter port 1 connects to receiver port 1.
Transmitter port 2 connects to receiver port 2.
Transmitter port 3 connects to receiver port 3.
5. Power on the remote display.
6. Boot up the source device. The source boots with the
resolution and refresh rate of the remote display.
N
Because the remote display is the source of EDID, it
must be powered on before the source device is booted.
7. Power on the local monitor, if required.
N
If used, the local monitor must be capable of handling
a resolution equal to or greater than that of the remote
display.
ON
1 2 3
ON
OFF
DEFAULT EDID
EDID MINDER
REMOTE DDC