DVI DL 201 Tx/Rx • Conguration and Operation
Configuration and Operation, cont’d
3-4
Using pass-through mode with DDC routed to a
local monitor
1. Set the EDID Minder switch to the off (down)
position and the Default EDID switch to the
off (down) position (see the gure at right).
The position of the Remote DDC switch is not
relevant.
2. Connect the source device to the transmitter
input.
3. Connect the display device to the receiver
output and, if required, the local monitor to the transmitter
output.
4. Connect the transmitter to the receiver with the three
twisted pair cables.
Transmitter port 1 connects to receiver port 1.•
Transmitter port 2 connects to receiver port 2.•
Transmitter port 3 connects to receiver port 3.•
5. Power on the local monitor.
6. Boot up the source device. The source boots with the
resolution and refresh rate of the local monitor.
N
Because the local monitor is the source of EDID, it must
be powered on before the source device is booted.
7. Power on the display device.
N
The remote display device must be capable of handling
a resolution equal to or greater than that of the local
monitor.
ON
1 2 3
ON
OFF
DEFAULT EDID
EDID MINDER
REMOTE DDC