DVI DL 201 Tx/Rx • Installation
2-19
RS-232 signals
RS-232 signals are bidirectional —
signals pass from the control device and
replies return from the remote device.
To connect the control device to the
transmitter, or the receiver to the remote
device, make the following connections,
as shown at right:
Tx to Tx•
Rx to Rx•
• (ground) to
N
For information about controlling display devices with
RS-232 commands, please refer to the user's manual of
that device.
IR signals
IR signals are one-way (from control device
to the IR emitter that broadcasts the IR
signal remotely). There are no responses
and no requirement for a reverse pathway.
To connect the control device to the
transmitter or the receiver to the IR emitter,
make the following connections, as shown
at right:
The Signal (S), from the control device to •
Tx of the transmitter.
The ground (G) of the control device is •
connected to the ground ( ) of the transmitter.
The Tx of the receiver to the S of the IR emitter.•
The ground (• ) of the receiver to the ground (G) of the IR
emitter.
Tx Rx
CONTROL
PASS THRU
S G
DVI DL 201
Transmitter
or Receiver
IR Control
or IR emitter
Tx Rx
CONTROL
PASS THRU
Tx Rx
DVI DL 201
Transmitter
or Receiver
RS-232 Control