DVI DL 201 Tx/Rx • Conguration and Operation
10. Power up the transmitter and the receiver. A single power
supply can provide power to both units through the
remote power connection.
11. Connect the remote display to the receiver output. A local
monitor display can also be connected to the transmitter
output at this time.
12. Connect the DVI source to the transmitter input.
13. Check that the transmitter switches are in the positions
described in steps 4-6.
14. Power on the DVI source device. The source device reads
and uses the EDID information stored in the transmitter
memory and boots up with that resolution.
15. Power on the remote (and local) display device(s).
N
All display devices must be capable of handling
resolutions equal to or greater than that of the device
used to set the EDID.
Using the EDID Minder with the default EDID
1. Set the EDID Minder switch to the on (up)
position and the Default EDID switch to the
on (up) position (see the gure at right). The
position of the Remote DDC switch is not
relevant.
2. Connect the source device to the transmitter
input.
3. Connect the display device to the receiver
output and, if required, the local monitor to the transmitter
output.
4. Connect the transmitter to the receiver with the three
twisted pair cables.
Transmitter port 1 connects to receiver port 1.•
Transmitter port 2 connects to receiver port 2.•
Transmitter port 3 connects to receiver port 3.•
5. Power on all devices.
6. The source boots using EDID showing a native resolution
of 2560x1600, regardless of the display device.
N
All display devices must be capable of handling
resolutions equal to or greater than the default values.
ON
1 2 3
ON
OFF
DEFAULT EDID
EDID MINDER
REMOTE DDC
3-3