Emerson 2700 Satellite Radio User Manual


 
Installation Manual 45
Output Wiring – Model 2700 Configurable I/O Transmitters
Output Wiring – Configurable I/O SpecificationsOutput Wiring – Fieldbus/PROFIBUSOutput Wiring – Intrinsically Safe
Figure 6-5 Frequency output – Terminals 3 & 4 (Channel B) – Internal power
Figure 6-6 Frequency output – Terminals 3 & 4 (Channel B) – External power
Note: See Figure 6-13 for output voltage versus load resistance.
Counter
+
Output voltage level is +15 VDC ± 3%
00042
Note: See Figure 6-15 for recommended resistor versus supply voltage.
CAUTION
Excessive current will damage the transmitter.
Do not exceed 30 VDC input. Terminal current must be less than 500 mA.
Counter
Pull-up
resistor
3–30 VDC
+
+
000042