Dynacord DMM 4650 Stereo System User Manual


 
FACTORY PRESETS
The installed software v 1.2 provides pre-stored factory presets for sequences, alarms and gongs. Also
defined are basic settings (menu “System setup”) as well as input and output lines. For direct use of these
presets, installation examples are to be found on page 31.
Factory settings, defaults
The user can edit these defaults according to individual requirements.
The data of the menus “outputs” “standby” and “sum level” determines the status of the DMM 4650 in
stand-by mode (no sequence running). A running sequence could lead to a modification of the outputs.
Upon completion of the sequence, the outputs are switched back to their previous status (stand-by mode).
Menu Parameter 1
Parameter 2 Parameter 3
Parameter 4
Contrast 0%
Backlight 50%
Phones 75%
Priority Prio1 33 Prio2 66 Prio3 99
Password Prio1 1111 Prio2 2222 Prio3 3333
Outputs all Low (relay open), except B4 = High
Bypass off (relay open)
Sum Gain 0 dB
Attenuation alarms 0dB gongs 0dB messages 0dB announcements 0dB
Language German
RS 232 9600 Baud
List of trigger signals
Input Level
Delay
sec.
Trigger
type
starts
sequence
utilization
Function (see sequence)
A1 Off release, S21 to S25, S31 and S33 to S37 wait for High at A1, return message
for system ready, upon release the signal output starts
A2 high >00,1 dyn S20 stops each running sequence
A3 high >00,1 dyn S21 start alarm message M00
A4 high >00,1 dyn S22 start DIN alarm, pulse trigger
B1 high >00,1 dyn S23 start DIN alarm, high = start, low = stop,
B2 high >00,1 dyn S24 start alarm text sequence, high = start, low = stop,
B3 high >00,1 dyn S25 4-tone gong, pulse trigger
B4 high >00,1 dyn S26 Pre-gong (2-tone), pulse trigger
C1 high >00,1 dyn S27 start message M01, pulse trigger
C2 high >00,1 dyn S28 start message M02, pulse trigger
C3 high >00,1 dyn S29 remote recording M01, pulse trigger, first pulse = start, second pulse = stop
C4 high >00,1 dyn S30 remote recording M02, pulse trigger, first pulse = start, second pulse = stop
D1 high >00,1 dyn S31 start DIN alarm with announcement key at D2, pulse trigger
D2 Off announcement in S31, high = announcement, low = alarm
D3 high >00,1 dyn S32 start announcement DMM 4650 Mic, high = start, low = stop
D4 high >00,1 dyn S36 Morse key
36