Boss Audio Systems GT-100 Stereo Amplifier User Manual


 
SYSTEM
30
Parameter Value Explanation
SUB
CTL 1
OUT
This sets the controller number when operation data from the
footswitch connected to the SUB CTL 1, 2/SUB EXP jack is output
as Control Change messages.
OFF Control Change messages are not output.
CC#1–CC#31,
CC#64–CC#95
This sets the controller number when SUB CTL
1 pedal operation data is output as Control
Change messages.
SUB
CTL 2
OUT
OFF Control Change messages are not output.
CC#1–CC#31,
CC#64–CC#95
This sets the controller number when SUB CTL
2 pedal operation data is output as Control
Change messages.
SUB
EXP
OUT
This sets the controller number when operation data from the
expression pedal connected to the SUB CTL 1, 2/SUB EXP jack is
output as Control Change messages.
OFF Control Change messages are not output.
CC#1–CC#31,
CC#64–CC#95
This sets the controller number when external
SUB EXP Pedal operation data is output as
Control Change messages.
MIDI PROGRAM MAP BANK 0–3
When switching patches using Program Change messages transmitted by
an external MIDI device, you can freely set the correspondence between
Program Change messages received by the GT-100 and the patches to be
switched to in the “Program Change Map.”
Parameter Value Explanation
PC#1–PC#128
U01-1–U50-4,
P01-1–P50-4
This sets the patch number (P01-1 through
U50-4) for the corresponding Program Change
number.
MIDI BULK DUMP
You can use Exclusive messages to provide another GT-100 with identical
settings, and save eect settings on a MIDI sequencer or other device.
Parameter Value Explanation
FROM
SYSTEM System parameter settings
QUICK Settings for User Quick Setting
U01-1–U50-4 Settings for Patch Number U01-1 through U50-4
TEMP Settings for the patch that is currently selected
TO
SYSTEM System parameter settings
QUICK Settings for User Quick Setting
U01-1–U50-4 Settings for Patch Number U01-1 through U50-4
TEMP Settings for the patch that is currently selected
PEDAL CALIBRATION
You can readjust the [EXP] pedal so that it will operate optimally.
Parameter Value Explanation
THRESHOLD 1–16
Adjusts the sensitivity at which the EXP PEDAL SW will
respond.
AUTO OFF
The GT-100 can turn o its power automatically. The power will turn
o automatically when 10 hours have passed since you last played or
operated the unit. The display will show a message approximately 15
minutes before the power turns o.
With the factory settings, this function is turned “ON” (power-o in 10
hours). If you want to have the power remain on all the time, turn it “OFF.”
* When the power is turned o, any settings you were editing will be lost.
You must save settings that you want to keep.
Parameter Value Explanation
AUTO OFF
OFF The power will not turn o automatically.
ON
The power will automatically turn o when
10 hours have passed since you last played or
operated the GT-100.
FACTORY RESET
Initializes the GT-100 to its factory-set condition. Refer to “Restoring the
Factory Settings.
Parameter Value Explanation
FROM
SYSTEM System parameter settings
QUICK Settings for User Quick Setting
U01-1–U50-4 Settings for Patch Number U01-1 through U50-4
TO
SYSTEM System parameter settings
QUICK Settings for User Quick Setting
U01-1–U50-4 Settings for Patch Number U01-1 through U50-4