10.2 Ordering Guide
As an example, assume a system is to be ordered for deployment in North America. The site
is a three sector site employing three UMWD-06516-XDM antennas. For this example, let’s
say the distance from the local controller to the junction box is 77m and the distance from the
junction box to the three actuators is 2 meters. This system would require the following.
Quantity Part Number Description
1 ATC200-Lite-0004 Local Controller
1 ATJB200-A01-004 4-Way Junction Box
3 ATM200-001 Actuators
Optional ATLP-200-001 Lightning Protection Unit
1 ATCB-B01-080 80 Meter Cable
3 ATCB-B01-004 4 Meter Cables
1 or more 602299 Grounding Kit
2 40417 Tiewraps, Bag of 50
The80mlengthisselectedsinceitisthesmallestsizegreaterthan77m.Fieldttingof
connectors is not recommended in order that reliable, weatherproof connections can be
maintained.
Although the distance between antennas is 2 m, you will generally require a cable longer than
this ‘straight line’ distance.
The junction box requires grounding. If a lightning protection unit is used, it must also be
grounded.