SETUP COMMANDS – BASIC
Basic General
Command Parameters Description Parameter values
VDS VDSy
Volume Display y may have the values 0 to 2, as follows:
0 = Normal, 1 = dB ref, 2 = Fine.
MXV zMXVy
Max Volume y may have a value in the range -33 to +19:
-33 = –33dB
+19 = +19dB
MXO zMXOy
Max On Volume y may have a value in the range -53 to +19:
-53 = –53dB
+19 = +19dB
DYU DYUy
Delay Units y may have the values 0 to 2, as follows:
0 = Imperial, 1 = Metric, 2 = Time.
OMD OMDy
OSD Mode y may have the values 0 to 1, as follows:
0 = Full Page, 1 = Mixed.
VST VSTy
Video Status y may have the values 0 to 1, as follows:
0 = Scart, 1 = Screen Control.
HQV HQVy
HQ Video y may have the values 0 to 1, as follows:
0 = RGB, 1 = Component.
SYG SYGx
Sync On Green
Basic Speakers
Command Parameters Description Parameter values
AST ASTy
Auto Setup y may have the values 0 to 5, as follows:
0 = THX, 1 = THX SurrEX, 2 = Config. 1, 3 = Config. 2, 4 = Config. 3, 5 = Custom.
SSZ SSZsy
Speaker Size y may have the values 0 to 2, as follows:
0 = None, 1 = Small/Present, 2 = Large.
5P1 5P1y
5.1 Rears y may have the values 0 to 2, as follows:
0 = SurrL/R, 1 = SurrBackL/R, 2 = Both.
Basic Delay
Command Parameters Description Parameter values
DLY DLYsy
Speaker Delays y may have a value in the range below, depending on the chosen delay units:
Imperial: 0 to 117 feet in 1ft steps
Metric: 0 to 12.7 meters in 0.1m steps
Time: 0 to 105 milliseconds in 1ms steps
Basic Levels
Command Parameters Description Parameter values
LVL LVLsy
Speaker Level settings y may have a value in the range -10 to +10:
-10 = –10dB
+10 = +10dB