Arcam E-2 Home Theater System User Manual


 
E-38
E-38
E-39
English
Basic Sub
Command Parameters Description Parameter values
CRF CRFy
Crossover Frequency y may have a value in the range 0 to 11:
0 = 40Hz
11 = 150Hz
(in 10Hz steps)
STM STMy
Stereo Mode y may have the values 0 to 2, as follows:
0 = Large+Sub, 1 = Sat+Sub, 2 = Large.
LFE LFEy
LFE Level y may have a value in the range -10 to 0:
-10 = –10dB
0 = 0dB
DLF DLFy
DTS LFE Gain y may have the values 0 to 1, as follows:
0 = 0dB Normal, 1 = –10dB.
SST SSTy
Sub Stereo y may have a value in the range -10 to 0:
-10 = –10dB
0 = 0dB
DAL DALy
DVD-A Sub Level y may have the values 0 to 1, as follows:
0 = 0dB Normal, 1 = +10dB.
NSW NSWy
No. of Subwoofers y may have the values 1 to 3, for 1 to 3 subwoofers.
Basic THX
Command Parameters Description Parameter values
TEX TEXx
THX Surround EX Flag detection
U2S U2Sx
THX Ultra 2 Sub
BGC BGCx
Boundary Gain Compensation
ASA ASAy
Advanced Speaker Array y may have the values 0 to 2, as follows: