A SERVICE OF

logo

20 HCI disassembly/assembly ENWW
5 Remove the separation roller rubber from
the separation roller.
6 Reinstall the separation roller in the
reverse order of the removal procedure.
CAUTION Make sure the separation
roller rubber is oriented
properly when reinstalling
it.
Check whether scratches
are visible on the pet cover
for the drive gear.
Check whether grease is
present on separation
roller.
Replacing the HCI feed MC
(MC101)/HCI first paper feed MC
(MC102)
Procedure
1 Open the top cover.
2 Remove the spring from the pick roller
unit.
3 Remove two screws to detach the top
cover.
CAUTION If the top cover is removed,
actuating the top cover
interlock switch can cause
the paper tray to lift beyond
the upward limit and
damage the HCI.
Screws
Top cover