A SERVICE OF

logo

ENWW Corona unit 165
MFP disassembly/assembly
6 Release and remove three wires from
each cleaning block.
CAUTION Be careful not to drop and
lose the support rubber
when removing the wire.
7 Turn the transfer/separation corona unit
upside down, remove the snap rings, and
remove the transfer wire cleaning block
and separation wire cleaning block from
the front side.
8 Reinstall the above parts following the
removal steps in reverse.
CAUTION When installing the
transfer/separation wires,
check that the coupling of
the cleaning pad drive gear
is engaged correctly.
Transfer wire
Transfer wire
Separation wire
Support rubber
Spring
Separation wire