A SERVICE OF

logo

160 MFP disassembly/assembly ENWW
Removing and reinstalling the
charge control plate
CAUTION Be sure the power cord has
been unplugged from the
wall outlet.
Procedure
1 Remove the charging corona unit.
2 Remove the two springs and remove the
charge control plate.
3 Reinstall the above parts following the
removal steps in reverse.
Replacing the charging wires
CAUTION Be sure the power cord has
been unplugged from the
wall outlet.
Procedure
1 Remove the charging corona unit.
2 Remove the charge control plate.
3 Remove the spark arrester plates (front
and rear).
4 Remove the charge control plate cleaner.
Charge control plate
Springs
Spark arrester plate (front)
Spark arrester plate (rear)