Sony MZ-R91 MiniDisc Player User Manual


 
16
• Description of Indication History
History code number Description
1st0 The first error
1st1 Total recording time when 1st0 was generated (Higher rank byte)
1st2 Total recording time when 1st0 was generated (Lower rank byte)
N 0 The last error
N 1 Total recording time when N 0 was generated (Higher rank byte)
N 2 Total recording time when N 0 was generated (Lower rank byte)
N-10 One error before the last.
N-11 Total recording time when N-10 was generated (Higher rank byte)
N-12 Total recording time when N-10 was generated (Lower rank byte)
N-20 Two errors before the last.
N-21 Total recording time when N-20 was generated (Higher rank byte)
N-22 Total recording time when N-20 was generated (Lower rank byte)
REC Total recording time *
• Description of Error Indication Codes
[Clearing Self-Diagnosis Data and Total Recording Time]
1. Setting the test mode. (See page 11.)
2. Move up the jog key on the set or press the [DISPLAY] key on the remote commander activates the self-diagnosis display mode.
3. Press the X key or [REC] key on the set during display of self-diagnosis data when clearing the self-diagnosis data, or during display of
total recording time when clearing the total recording time. Thus, ClrOK? will be displayed on the LCD, and press the same key again,
and when self-diagnosis data is cleared ErrCLR is displayed and the data is cleared. Also when total recording time is cleared, ReeT
O is displayed and it is cleared.
* Total recording time
Total recording time is recorded in
minutes. It is recorded in hexadecimal
format and up to 65,535 min. can be
counted. It returns to 0000h when
recorder goes beyond this limit.
Problem Indication code Meaning of code Description
No error 00 No error
01
Illegal access target address Attempt to access an abnormal address
was specified
Servo error 02 High temperture High temperture
03 Focus error Forcus could not be applied
04 Spindle error Abnormal lotation of disc
21 Initial low battery Abnormal voltage at initialization
Power error
22 Low battery Momentary interruption detected
23 Low battery NI Momentary interruption detected (NiMH)
24 Low battery AM Momentary interruption detected (AM)