Outline
In this set, automatic adjustment of CD and MO can be per-
formed by entering the test mode.
However, before starting automatic adjustment, the memory
clear, power supply adjustment, and laser power check must be
performed in the manual mode.
A key having no particular description in the text, indicates a
set key.
For the LCD display, the LCD on the remote commander is
shown, but the contents of LCD display on the set are same.
Precautions for Adjustment
1. Adjustment must be done in the test mode only.
After adjusting, release the test mode.
2. Use the following tools and measuring instruments.
Test CD disc TDYS-1
(Part No. : 4-963-646-01)
SONY MO disc available on the market
Digital voltmeter
Laser power meter LPM-8001
(Part No. : J-2501-046-A)
Thermometer (using the Temperature Correction)
3. Unless specified otherwise, supply DC 3V from the DC IN
3V jack (J601).
4. Switch position
HOLD switch ............................................... ON
Adjustment Sequence
1. NV Reset (EEPROM clear)
Manual Mode
r
2. Power Supply Manual Adjustment
Manual Mode
r
3. Temperature Correction (item number: 015)
r
Manual Mode
4. Laser Power Check
r
5. Electrical Offset Adjustment
Caution: This adjustment must be made with
no disc loaded.
r Overall Mode
6. CD Overall Adjustment
r
7. MO Overall Adjustment
r
Manual Mode
8. RESUME Clear
Note: If the version of the microcomputer is 1.000 or later, “3. Tempera-
ture Correction” and “2. Power Supply Manual Adjustment” can
be performed continuously in reverse order with pressing the [PLAY
MODE]
key on the remote commander in the overall adjustment
mode.
NV Reset
Caution: The shipment data will be cleared when the NV is reset.
Therefore, change the NV adjusted values following the
Change of NV Adjusted Values immediately after the
NV was reset.
Change the NV adjustment values according to the mi-
crocomputer version.
Setting method of NV reset
1. Select the manual mode of the test mode, and set item number
021 NV Reset (see page 14).
2. Press the X key.
3. Press the X key once more.
4. Press the
x/CHG key to quit the manual mode, and return
the test mode (display check mode).
Change of NV adjusted values (version 1.000)
Caution: Change the NV adjustment values according to the mi-
crocomputer version.
In this set, some adjusted values were set in the manual mode at
the shipment, but these will be cleared when the NV is reset. There-
fore, modify the NV adjusted values through the following proce-
dure immediately after the NV was reset.
1. Item numbers in which the NV adjusted values are to be modi-
fied
Change ABCD gain [Hpit] initial value (item number 336)
Caution:The ABCD gain [Hpit] initial value must be
changed before the overall adjustment.
Change DFTC threshold value (item number 151)
Turn off sound generation speed-up (item numbers 861 to
864)
Change CLV drive voltage limiter (item numbers 865, 866)
Change x2 CLV speed gain, +6dB compared to conventional
(item numbers 867, 868)
Change x2 CLV phase gain, +3dB compared to conventional
(item numbers 871, 872)
Change x2/x1 switching temperature threshold value
(+10°C t +5°C) (item numbers 873, 874)
Remote commander LCD display
NV reset (after several seconds)
Res***
021
Reset!
021
Remote commander LCD display
ResNV CC
021
Remote commander LCD display
ResOK?
021