Sony HCD-MD373 Stereo System User Manual


 
39 39
NOTE:It is useful to use the jig. for checking the waveform. (Refer
to Servicing Note on page 11.)
[BD (MD) BOARD] (SIDE B)
CN110
NOTE
D101
I+3V
IOP
TE
VC
GND
IC171
IC121
IC101
IC192
CN101
RF
5-15. ADJUSTING POINTS AND CONNECTING POINTS
[BD (MD) BOARD] (SIDE A)
CD SECTION
Note:
1. CD Block is basically constructed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M impedance.
4. Clean the object lens by an applicator with neutral detergent when
the signal level is low than specified value with the following
checks.
S Curve Check
Procedure :
1. Connect the oscilloscope to test points TP (FE) and TP (VC).
2. Connect TP (FEI) and Ground, and TP (AGCCON) and Ground
of the BD board with lead wires.
3. Press the 1/u button to turn the set ON.
4. With the disc (YEDS-18) loaded, press the ^ (CD) button
and perform focus search. (Focus search will be performed in
the same way even while the disc table is pushed in and out.)
5. Check the symmetry and peak to peak level of the oscilloscope
waveform (S curve) at this time.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note: Try to measure several times to make sure than the ratio of
A : B or B : A is more than 10 : 7.
Take sweep time as long as possible and light up the bright-
ness to obtain best waveform.
Checking Location : BD (CD) board
RF Level Check
Procedure :
1. Connect oscilloscope to test point TP (RF) and TP (VC) on BD
board.
2. Connect TP (AGCCON) and Ground of the BD (CD) board with
lead wires.
3. Press the 1/u button to turn the set ON.
4. Put disc (YEDS-18) in and playback 5track.
5. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
6. After check, remove the lead wire connected in step 2.
oscilloscope
BD (CD) board
TP (FE)
TP (VC)
+
symmetry
A
B
Within 4
±
1 Vp-p
oscilloscope
BD (CD) board
TP (RF)
TP (VC)
+
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.45
±
0.3 Vp-p
0V
Center of the waveform
B
Symmetry
A (DC voitage)
level : 1.3
±
0.6 Vp-p
oscilloscope
BD (CD) board
TP (TE)
TP (VC)
+
Note: Clear RF signal waveform means that the shape “” can be
clearly distinguished at the center of the waveform.
RF signal waveform
Checking Location : BD (CD) board
E-F Balance (1 Track Jump) check
Procedure:
1. Connect oscilloscope to test point TP (TE) and TP (VC) on BD
(CD) board.
2. Press the 1/u button to turn the unit ON.
3. Put disc (YEDS-18) in to play the number five track.
4. Press the ^ (CD) button.
5. Check the level B of the oscilloscope's waveform and the A (DC
voltage) of the center of the Traverse waveform.
Confirm the following:
A/B x 100 = less then ± 22 (%)
B = 1.3 ± 0.6 Vp-p
1 track jump waveform
Checking Location : BD (CD) board
Checking Location : BD (CD) board
[ BD (CD) BOARD ] — SIDE B —
TP
(VC)
TP
(RF)
TP
(TE)
TP
(FEI)
TP (FE)
TP
(AGCCON)
IC103