Sharp MD-MT877C MiniDisc Player User Manual


 
MD-MT877/MD-MT877C
– 23 –
S F
f i
E F
DISP
DISP
S E
e i
E F
DISP
DISP
DISP
DISP
• LPFFINO/EFMIO measurement value
• LPFEINO/EFMIO measurement value
G C H
e f
DISP DISP
P C H
S B
a b
DISP DISP
S A
• LPFEFO measurement value
• LPFABO measurement value
S b
A B
DISP DISP
S a
• ABMAXO measurement value
: EFMIO measurement value indication
"REPEAT", "1" Mark lighting
: LPFFINO measurement value indication
"1" Mark lighting
: F-ATT (tracking) initial setting
: EFMIO measurement value indication
"REPEAT", "1" Mark lighting
: LPFEINO measurement value indication
"1" Mark lighting
: E-ATT (tracking) initial setting
: LPFEFO measurement value indication
"1" Mark lighting
: Pit section adjustment COUT level setting
: Group section adjustment COUT level setting
: LPFABO measurement value indication
"1" Mark lighting
: ABMAXO measurement value indication
"1" Mark lighting
: A-ATT (focus) tentative setting
: B-ATT (focus) tentative setting
: A-ATT (focus) tentative setting
: B-ATT (focus) tentative setting
: ATT manual adjustment menu
: Temperature code indication
$ $ : Temperature code
: Laser ON (play power)
: Pit section E-ATT (tracking) setting
: ATT setting
: Pit section F-ATT (tracking) setting
: ATT setting
: High reflection A-ATT (focus) setting
: Low reflection A-ATT (focus) setting
: ATT setting
: TCRS ATT setting
: ATT setting
:Groove section E-ATT (tracking) setting
: ATT setting
:Groove section F-ATT (tracking) setting
: ATT setting
: Low reflection A-ATT (focus) setting
: ATT setting
: Low reflection B-ATT (focus) setting
: ATT setting
PLAY
M A N U 2
Servo ATT Manual Adjustment
T M P $ $
L O N P
SKIP UP SKIP DOWN
P E
SKIP UP SKIP DOWN
P F
SKIP UP SKIP DOWN
H A
L a
SKIP UP SKIP DOWN
: High reflection B-ATT (focus) setting
: Low reflection B-ATT (focus) setting
: ATT setting
H B
L b
SKIP UP SKIP DOWN
G C
SKIP UP SKIP DOWN
G E
SKIP UP SKIP DOWN
G F
SKIP UP SKIP DOWN
L A
SKIP UP SKIP DOWN
L B
SKIP UP SKIP DOWN
* When the [STOP] button is pressed in specific condition, the "TEST MODE STOP" state is set.
* If the [PLAY] button is pressed in the B-ATT setting state, the mode is changed to the continuous
playback mode.
And if the [P-MODE] button is pressed in the continuous playback state, the mode is changed to
the B-ATT setting state of the ATT manual adjustment.