Sennheiser EK 3241 Stereo Receiver User Manual


 
20
If a problem occurs ...
Error checklist
If a problem occurs that is not listed in the above table or if
the problem cannot be solved with the proposed solutions,
please contact your local Sennheiser agent for assistance.
Problem Possible cause Possible solution
No display
indication
The receiver’s power
supply is interrupted
Check if the receiver is
correctly inserted into
the camcorder
(see page 6)
or check if the
GA 3041-B battery
adapter is correctly
mounted (see page 7)
No RF
signal
indication
No RF signal:
transmitter and
receiver are not on
the same channel
Set transmitter and
receiver to the same
channel
No RF signal:
the transmitter is out
of range
Reduce the distance
between transmitter
and receiver
RF signal
indication
available,
no audio
signal
The receiver’s
squelch threshold is
adjusted too high
See “Adjusting the
squelch threshold –
SquELH” on page 17
Audio
signal has
a high level
of back-
ground
noise
The transmitter
sensitivity is
adjusted too low
Adjust the
transmitter
sensitivity correctly
The maximum
effective range of the
RF link has been
reached
Reduce the distance
between transmitter
and receiver
Audio
signal is
distorted
The transmitter
sensitivity is
adjusted too high
Adjust the
transmitter
sensitivity correctly
The receiver is
overmodulated
Increase the distance
between transmitter
and receiver (see
page 21)