Philips LTC 2600 Stereo Receiver User Manual


 
21
4.3 Action Setup
The LTC 2600 Series multiplexer includes a Digital Motion Detection feature that detects movement within the
camera scene. When this feature is programmed and motion is detected, the record/display rates will increase.
Using the ACTION LIST facility, the priority of recording can be changed to include recording of camera pictures
and at the same time prioritize picture display on the monitor.
Action Dwell: The action will be held for monitor display (full video on monitor B, when applicable) and
recording for the programmed duration (3 to 60 seconds).
Action List: Selects cameras to have motion detection. Entering the ACTION LIST menu enables this list to
be customized to a specific configuration.
Action Record: Defines if a selected camera is recorded to the VCR when an action input is detected. Action
camera(s) can be set to record in Exclusive or Interleave mode (refer to VCR setup section for programming
VCR response to action).
Exclusive mode allows recording only the camera inputs in which an action has been detected.
Interleave mode, all camera(s) in the record list are recorded; however, the camera(s) that are in action are
alternated between the non-action cameras.
Action Zones: The screen is divided into a 14 X 16 grid (224 zones). Enabling or Disabling zones will allow
the installer to specify which areas of the scene will detect action. For example, for an outdoor application,
some of the scene includes a view of the sky. In this case the grid areas covering the sky can be disabled.
Once in the Action Zone setup, select the camera requiring Action Zone setup by depressing the
corresponding camera number.
To Enable zones, select the Menu key, ensure ZONE (EDIT:MENU) = ENABLE (X) is displayed. Move the
cursor using the up, down, left, and/or right arrow keys to enable zones. Enabled zones will display an X.
To Disable zones, select the Menu key, ensure ZONE (EDIT:MENU) = DISABLE (O) is displayed. Move
the cursor using the up, down, left, and/or right arrow keys to disable zones. Disabled zones will be
blank.
To select the Default Enabled Zones, select the FREEZE key (12 X 14 grid, 168 zones).
To exit the Action Zone setup, select the ZOOM key.
To edit the enabled zones Sensitivity and Number of Zones for Alarm, proceed to the Walkthrough
setup.
Walkthrough: The Walkthrough section of the Action Alarm Setup will be required to set Action Zone
Sensitivity and Number of Zones for Alarm within the scene which require activation before the system will
acknowledge an Action Alarm. Sensitivity and zone activation settings may be tested and adjusted from this
menu screen.
Once in the Walkthrough setup, select the camera requiring Action Alarm setup by depressing the
corresponding camera number.
To adjust the Action Alarm zone Sensitivity requirement, selecting the key will decrease and using the
key will increase the zone sensitivity.
To establish Number of Zones for Alarm, selecting the < will decrease and using the > will increase the
amount of zones required to initiate an Action Alarm. Note:The Number of Zones for Alarm must be
equal to or less than the number of enabled zones.
Default settings for Sensitivity (MED) and Number of Zones for Alarm (10) can be achieved by
depressing the FREEZE key.
To exit the Walkthrough Program, select the ZOOM key.
LTC 2600 Series Section 4 Advanced Programming
<
<