76 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA
Table 8-11: Detailed Settings for Mini CO SSPA mode (Device Type=8)
settingIndex/settingValue settingTextValue Value OID Description
1/INTEGER SystemMode'1:1=0,Dual 1:1 = 1,MSwitch=2,StandAlone=255 1.3.6.1.4.1.20712.2.1.1.1.2.1 System Operation mode
2/INTEGER SystemHierarchicalAddress'HPA1=0,HPA2=255 1.3.6.1.4.1.20712.2.1.1.1.2.2 System Hierarchical Address
3/INTEGER CurrentState'UnitStandby=0,UnitOnline=255 1.3.6.1.4.1.20712.2.1.1.1.2.3 Unit Start Up State in Redundancy
4/INTEGER Mute'On=0,Off=255 1.3.6.1.4.1.20712.2.1.1.1.2.4 Mute State
5/INTEGER SSPAAttenuation(dBx10)'0..200 1.3.6.1.4.1.20712.2.1.1.1.2.5 Attenuation Level
6/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.6 Field reserved for future use
7/INTEGER NetworkAddress'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.7 Amplifier Network Address
8/INTEGER HighTempAlarmThreshold(C)'0..100 1.3.6.1.4.1.20712.2.1.1.1.2.8 High Temperature Alarm Threshold
9/INTEGER CalibrationMode'On=0,Off=255 1.3.6.1.4.1.20712.2.1.1.1.2.9 SSPA module Calibration Mode
10/INTEGER SpareFaultCheck'ADCCh0-1=0..1,Ext.Mute=8,Ignore=255 1.3.6.1.4.1.20712.2.1.1.1.2.10 SSPA Spare Fault Status
11/INTEGER SpareFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255 1.3.6.1.4.1.20712.2.1.1.1.2.11 SSPA Spare Fault Handling
12/INTEGER AuxFaultCheck'LogicHigh=0,LogicLow=1,Ignore=255 1.3.6.1.4.1.20712.2.1.1.1.2.12 SSPA Auxiliary Fault Status
13/INTEGER AuxFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255 1.3.6.1.4.1.20712.2.1.1.1.2.13 SSPA Auxiliary Fault Handling
14/INTEGER BUCFaultCheck'Enable=0,Disable=255 1.3.6.1.4.1.20712.2.1.1.1.2.14 Block Up Converter Fault Status
15/INTEGER BUCFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255 1.3.6.1.4.1.20712.2.1.1.1.2.15 Block Up Converter Fault Handling
16/INTEGER ProtocolSelect'IPNET=3,SNMP=4,Serial=255 1.3.6.1.4.1.20712.2.1.1.1.2.16 Protocol Select
17/INTEGER BaudRate'38400=255,19200=1,4800=2,2400=3,9600=255 1.3.6.1.4.1.20712.2.1.1.1.2.17 Baud Rate Select
18/INTEGER FiberFaultCheck'LogicHigh=0,LogicLow=1,Ignore=255 1.3.6.1.4.1.20712.2.1.1.1.2.18 Fiber Converter Fault Status
19/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.19 Fiber Converter Fault Handling
20/INTEGER StandbyMode'ColdStandby=0,HotStandby=255 1.3.6.1.4.1.20712.2.1.1.1.2.20 Standby Mode
21/INTEGER BUCReference'Autoswitch=0,External=1,Internal=2,NA=255 1.3.6.1.4.1.20712.2.1.1.1.2.21 BUC Reference
22/INTEGER
FwdRFCheck'LowRF=0,Window10%=1,Window15%=2,
HighRF=3,Dis=255
1.3.6.1.4.1.20712.2.1.1.1.2.22 Type of forward RF fault
23/INTEGER RFFaultAction'MajorFault=0,MinorFault=255 1.3.6.1.4.1.20712.2.1.1.1.2.23 Forward RF fault handling
24/INTEGER FrwdRFFaultThreshold(dBm)'0..80 1.3.6.1.4.1.20712.2.1.1.1.2.24 Forward RF Fault threshold level in dBm
25/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.25 Field reserved for future use
26/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.26 Field reserved for future use
27/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.27 Field reserved for future use
28/INTEGER Reserved'0..255 1.3.6.1.4.1.20712.2.1.1.1.2.28 Field reserved for future use