Lexicon
PCM 80 User Guide
2-32
Turn ADJUST to scroll through all of the parameters in the Edit matrix of the
currently loaded effect, including the Modulation parameters.
Once you have assigned a parameter as a Destination, the controller you have
assigned “owns” that parameter. Adjustments made to this parameter from the
Edit matrix, will only affect the initial value of the parameter when the program
is loaded.
The behavior of the parameter on program load is determined by the setting of
the Patch Update parameter in Control mode (1.7). This parameter can be set
to Immediate or Delayed.
When Immediate is selected, the initial value of the parameter value will
correspond to the controller position.
When Delayed is selected, the stored value of the parameter will continue to be
in effect until the controller is moved. (It is, therefore, a good idea to set a sensible
value to the parameter in the Edit matrix.)
Assigning a Destination Once you have selected a Source, press Load /✱ and the display will change
to allow you to assign a Destination (Dst).
Rvb Time Ref Lvl L
Patch 0 ✱Dst
SELECT will move you across
the Patch row (0-9).
The name of the current Destination assign-
ment is shown here. (✱✱✱Unassigned✱✱✱
will appear across the bottom display line if no
assignment is selected.)
The Edit matrix row label for the
currently assigned parameter is
shown here.
The asterisk (✱) indicates that Destinations will be se-
lected when you turn ADJUST. Press Load /✱ to bring up
the Values display where you can assign Src Value and
Dst Value. Press Load /✱ again to return to Source
selection, etc.
Mod Row parameters that can be assigned as Patch Destinations
LFO Rate, Shape, P Width, Depth
AR ENV Attack, Release, Mode
Env L Release
Env R Release
Sw 1 Rate, P Width, Mode
Sw 2 Rate, P Width, Mode