5 - 5
ADJUSTMENT ITEM
ADJUSTMENT CONDITION
VALUE
[t44] 13
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
Push [FUNC]+[BAND]
(Automatic adjustment)
[t54] 14
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[t64] 15
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
Push [FUNC]+[BAND]
(Automatic adjustment)
[t15] 16
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[t25] 17
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[t35] 18
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[t45] 19
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
FM S-METER
[S1]
1
•
•
Set the SSG as;
Frequency : Specifi ed frequency* Level : 0 dBµ
†
(−107 dBm)
Receiving
Push [BAND]
[S2] 2
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[S3] 3
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[S4] 4
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[S5L] 5
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[S5H] 6
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[S6] 7
•
•
Set the SSG as;
Frequency : Specifi ed frequency* Level : +5 dBµ
†
(−102 dBm)
Receiving
WFM S-METER
[S2]
1
•
•
Set the SSG as;
Frequency : Specifi ed frequency* Level : +1 dBµ
†
(−106 dBm)
Receiving
Push [BAND]
[S3] 2
•
•
Set the SSG as;
Frequency : Specifi ed frequency* Level : −3 dBµ
†
(−104 dBm)
Receiving
[S4] 3
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[S5L] 4
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[S5H] 5
•
•
Set the SSG as;
Frequency : Specifi ed frequency*
Receiving
[S6] 6
•
•
Set the SSG as;
Frequency : Specifi ed frequency* Level : +8 dBµ
†
(−99 dBm)
Receiving
• RECEIVE ADJUSTMENT (continued)
*Displayed on the function display.
†