Extron electronic VSC 150 Stereo Receiver User Manual


 
VSC 150 Remote Control
VSC 150 Remote Control
Remote Control, cont’d
3-5
Vertical filter (detail)
Select vertical filter
X2
(Dvt)
X2
d
X2
+ 64 Dvt
X2
Specific value
Select next higher vertical filter (Dhz + 1) { d 7B + 64 Dvt
X2
Increment up
Select next lower vertical filter (Dhz - 1) } d 7D + 64 Dvt
X2
Increment down
Encoder filter (detail)
Select encoder filter
X3
(Enc)
X3
e
X3
+ 65 Enc
X3
Specific value
Select next higher encoder filter (Enc + 1) { e 7B + 65 Enc
X3
Increment up
Select next lower encoder filter (Enc - 1) } e 7D + 65 Enc
X3
Increment down
Memory
Save preset
X4
,
X4
2C Spr
X4
Recall preset
X4
.
X4
2E Rpr
X4
Freeze
Set Freeze mode to On (freeze the displayed image) F 46 Frz 1 Enable freeze
Set Freeze mode to Off (release the displayed image) f 66 Frz 0
Disable freeze
Executive mode
Set Executive mode to On X 58 Exe 1 Enable executive
Set Executive mode to Off x 78 Exe 0
Disable executive
Firmware version, part number & information requests, and reset
System reset Esc z 1B 7A 0D Zap Reset to factory default
Query firmware version number Q/q 51/71 Ver x.xx
Display firmware version
Request part number N/n 4E/6E N60-312-01
Display VSC 150s part #
Request information Command = I/i 49/69 (see below)
Display status
Response = Dhz
X1
Dvt
X2
Enc
X3
Frz
X5
Exe
X5
X2
= Vertical filtering level (1 through 3)
X3
= Encoder filtering level (1 through 3)
X4
= Memory presets (1 through 3)
X5
= 1 = On, 0 = Off
Symbol definitions
= CR/LF (carriage return/line feed)
= CR (carriage return only)
•=Space
X1
= Horizontal filtering level (1 through 2)
3-4
Command/response table
Command description Command Response Additional
ASCII Hex
(VSC to host) description
Horizontal shift
Shift right one step { H 7B + 48 Hph + Increment up
Shift left one step } H 7D + 48 Hph -
Increment down
Vertical shift
Shift down one step { / 7B + 2F Vph + Increment up
Shift up one step } / 7D + 2F Vph -
Increment down
Horizontal size
Increase horizontal size by one step { : 7B + 3A Hsz + Increment up
Decrease horizontal size by one step } : 7D + 3A Hsz -
Increment down
Vertical size
Increase vertical size by one step { ; 7B + 3B Vsz + Increment up
Decrease vertical size by one step } ; 7D + 3B Vsz -
Increment down
Horizontal filter (detail)
Select horizontal filter
X1
(Dhz)
X1
D
X1
+ 44 Dhz
X1
Specific value
Select next higher horizontal filter (Dhz + 1) { D 7B + 44 Dhz
X1
Increment up
Select next lower horizontal filter (Dhz - 1) } D 7D + 44 Dhz
X1
Increment down
Command description Command Response Additional
ASCII Hex
(VSC to host) description