Extron electronic DVS 304 AD Stereo Receiver User Manual


 
DVS 304 • Ethernet Control
4-5
The default address is 192.168.254.254, but if this conflicts with other equipment at
your installation, you can change the IP address to any valid value.
N Editing the Extron IP address while connected via the Ethernet port can im-
mediately disconnect the user from the scaler. Extron recommends editing this
field using the RS-232 link and protecting the Ethernet access to this screen by
assigning an administrator’s password to qualified and knowledgeable person-
nel only.
Edit this field as follows:
1. Click in the DVS 304 IP address field. The graphic cursor becomes a text
cursor.
2. Edit the address as desired.
3. Press the Tab key on the keyboard or click in another field to exit the IP
Address field.
4. Click on the Submit button to make the address change take affect.
Gateway IP Address
The Gateway IP Address field identifies the address of the gateway to the mail
server to be used if the DVS 304 and the mail server are not on the same subnet.
The gateway IP address has the same validity rules as the system IP address.
Subnet Mask field
The Subnet Mask field is used to determine whether the DVS 304 is on the same
subnet as the controlling PC or the mail server when you are subnetting.
Date/Time Settings elds
The Date/Time Settings fields (figure 4-3) provide a location for viewing and
setting the time functions. The adjustable variables are month, day, year, hours,
minutes, AM/PM, and (time) zone.
Change the date and time settings as follows:
1. Click the desired variable’s drop box. A drop down scroll box appears.
2. Click the desired value.
N
For quick setting of the date and time, click the Local Date/Time.
Click Cancel at any point before submitting to exit any field changes.
The unit is not updated with those changes The screen refreshes and shows the
current device settings.
3. Repeat steps 1 and 2 for all variables that need to be changed.
4. If appropriate, select the Daylight Savings radio button for the DVS’s region,
to turn on the daylight savings time feature.
N
When a locations daylight savings time is turned on, the switcher automatically
updates its internal clock between Standard Time and Daylight Savings Time
in the spring and fall on the date that the time change occurs in the country or
region selected. When Daylight Savings Time is turned off, the switcher does
not adjust its time reference.
5. Select the Zone variable that is relevant for the DVS’s location.
N
The Zone field identifies the standard time zone selected and displays the
amount of time, in hours and minutes, that the local time varies from the GMT
international time reference.
5. Click Submit. The device is updated with the new settings.