Crown Audio CTS4200A Speaker User Manual


 
page 43
CTs Power Amplifi ers
Operation Manual
5.2.4 Channel Level Control
The signal level for each input can be attenu ated
accurately by adjusting the 21-step Level
Control (see Section 4.2). Figure 5.2 shows the
amount of attenuation in dB for each detent.
Note: Attenuation per detent varies with
operat ing mode since gain varies with operating
mode. Attenuation amounts shown may vary
±6%.
Detent 4/8 Ohm 70V 100V
0 (full CCW) 68.31 72.90 71.02
1 67.54 72.06 70.26
2 32.23 36.61 34.90
3 25.46 29.74 28.00
4 21.83 25.87 24.22
5 19.23 23.20 21.58
6 17.12 20.94 19.40
7 15.36 19.02 17.53
8 13.76 17.22 15.79
9 12.28 15.53 14.20
10 10.84 13.90 12.62
11 9.51 12.32 11.16
12 8.28 10.87 9.81
13 7.09 9.45 8.45
14 6.30 8.11 7.22
15 4.92 6.70 5.94
16 3.82 5.26 4.63
17 2.62 3.70 3.21
18 1.35 1.90 1.66
19 0.01 0.01 0.01
20 (full CW) 0.00 0.00 0.00
ATTENUATION in dB
Figure 5.2 Level-control Attenuation per Detent in CTs Multichannel Amplifi ers
5 Advanced Features
and Options