page 30
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Data based on all channels driven.
Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Line current figures for 100VAC units (not shown) are 1.2 times the line current figures of 120VAC units.
Power draw (”watts in”) of 100VAC units is the same as power draw of 120VAC units.
watts in
watts out dissapated
Btu/hr kcal/hr
At Idle (sleep mode)
40 0 40 137 34
1/8th Power Pink Noise 8 Ohms/Ch.
1000x2
Typical of program material
16 Ohms Bridge
2000
just at clip.
4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch. 1000x2
140/200V Bridge 2000
1/3rd Power Pink Noise 8 Ohms/Ch.
1250x2
Typical of program material
16 Ohms Bridge
2500
with severe clipping.
4 Ohms/Ch.
1500x2
8 Ohms Bridge
3000
2 Ohms/Ch.
1500x2
4 Ohms Bridge
3000
70/100V/Ch. 1500x2
140/200V Bridge 3000
CTs 3000
Load
Rated
Power
Line Current
120VAC
Line Current
230VAC
Watts
Thermal Dissipation
7.2 3.6 579 313 266 907 229
8.5 4.2 697 381 316 1079 272
9.6 4.8 790 384 405 1384 349
7.2 3.6 579 313 266 907 229
13.7 6.8 1196 835 360 1230 310
16.2 8.1 1469 1010 459 1565 395
19.2 9.6 1686 1024 662 2259 570
13.7 6.8 1196 835 360 1230 310
8 AC Power Draw and Thermal Dissipation