AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Data based on all channels driven.
Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Line current figures for 100VAC units (not shown) are 1.2 times the line current figures of 120VAC units.
Power draw (”watts in”) of 100VAC units is the same as power draw of 120VAC units.
watts in
watts out dissapated
Btu/hr kcal/hr
At Idle (sleep mode)
40 0 40 137 34
1/8th Power Pink Noise 8 Ohms/Ch.
1000x2
Typical of program material 16 Ohms Bridge
2000
just at clip. 4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch. 1000x2
140/200V Bridge 2000
1/3rd Power Pink Noise 8 Ohms/Ch.
1000x2
Typical of program material 16 Ohms Bridge
2000
with severe clipping. 4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch. 1000x2
140/200V Bridge 2000
485 1655 417
11.6 5.8 990 674 316 1080 272
13.7 6.9 1190 705
304 1036 261
12.3 6.2 1064 672 392 1338 337
11.3 5.6 980 676
351 1198 302
6.7 3.4 639 257 382 1304 329
7.2 3.6 602 251
290 988 249
7.0 3.5 563 255 307 1049 264
6.6 3.3 546 256
CTs 2000
Load
Rated
Power
Line Current
120VAC
Line Current
230VAC
Watts
Thermal Dissipation
8 AC Power Draw and Thermal Dissipation