Crestron electronic htt-b10x Radio User Manual


 
Crestron HTT-B10X infiNET™ TableTop Controller
latest revision of the C2N-MNETGW infiNET Gateway/Transceiver
Operations Guide (Doc. 6317), which is available from the Crestron website
(www.crestron.com/manuals). The gateway ACQUIRE LED will light.
NOTE: C2N-MNETGW firmware version 2.001.0003 or later is required.
NOTE: Use a fixed communications channel for any gateway that will
communicate with a battery operated HTT-B10X. Failure to do so could result
in a loss of communications, should the gateway change channels. Auto channel
operation is acceptable for units intended to be powered via the 12 Volt power
pack at all times.
NOTE: In environments where multiple gateways are installed, only one
gateway should be in Acquire mode at a time.
3. Put the HTT-B10X in the Acquire mode by pressing button #2 and holding
it for five seconds (refer to illustration at the top of page 10). The LED next
to button #2 will light when the button is pressed and will blink off briefly
at the five second threshold when the button is held. When the LED blinks
off, release the button. During the acquire process, the LED will blink every
half second to indicate the acquire is in progress. When LED #2 stops
blinking, the acquire process is complete. This can take up to five minutes.
NOTE: To cancel the acquire process before it has completed, press button #2
again.
LED #8 will indicate the infiNET link status as follows:
Solid: communication with gateway and SIMPL program
Blinking every half second: communication with gateway but not
being “polled” by control system
Off: no communication with gateway
4. After the process is complete, take the C2N-MNETGW out of the Acquire
mode by pressing ACQUIRE on the gateway. Refer to the latest revision of
the C2N-MNETGW infiNET Gateway/Transceiver Operations Guide (Doc.
6317).
5. To communicate with the control system program, an MNET ID value
between 03 and 20 must be assigned to the HTT-B10X. Refer to “Identity
Code” on page 8. Use Creston Toolbox to set the MNET ID as follows:
Display the network device tree (Tools | Network Device Tree).
Right-click on the HTT-B10X and select Change Network ID….
Enter the desired MNET ID and press the Enter key.
Operations Guide – DOC. 6583B infiNET™ TableTop Controller: HTT-B10X 11