Setup Mode
Prior to using the HTT-B10X as part of a Crestron system, it must be configured for
use on an infiNET network. This is done via the Setup mode.
NOTE: Setup mode is only enabled when the unit is being powered from its 12 Volt
power pack.
HTT-B10X Setup Reference
Button #1:
Enables/Disables
Manner Mode
Button #2:
Press and hold to
start Acquire Mode
Buttons #9 and #10:
Press and hold
together to Enter/Exit
Setup Mode
Button #3:
Enables/Disables
Local Button
Feedback
LED #8:
Indicates infiNET
link status
1
2
34
5
6
78
9
10
Enter
To enter Setup mode, press and hold buttons #9 and #10 while connecting the
included 12 Volt DC power supply to the jack on the rear of the HTT-B10X.
Continue to hold buttons #9 and #10 for five seconds. The LEDs next to buttons #9
and #10 will blink every half second to indicate the unit is in Setup mode.
Exit
To exit Setup mode, press buttons #9 and #10. The LEDs next to buttons #9 and #10
will turn off.
Setup mode also incorporates a time-out. If there is no activity for one minute, the
HTT-B10X will exit Setup mode automatically.
The HTT-B10X will also exit Setup mode if the 12 Volt power pack is disconnected.
Basic infiNET™ Setup
Acquire Gateway Connection
Before an infiNET device can be used on an infiNET network, it must first be
acquired by a C2N-MNETGW gateway that is connected to a Cresnet network.
NOTE: An infiNET device can be acquired by only one gateway.
To acquire an HTT-B10X, perform the following procedure:
1. Enter Setup mode (refer to “Setup Mode” above).
2. While in Setup mode, put the C2N-MNETGW in the Acquire mode, from
the unit itself by pressing ACQUIRE or from Toolbox, as described in the
10 infiNET™ TableTop Controller: HTT-B10X Operations Guide – DOC. 6583B