Crestron electronic htt-b10x Radio User Manual


 
InfiNET™ TableTop Controller Crestron HTT-B10X
Setup
Identity Code
The MNET ID of the HTT-B10X has been factory set to 01. After an infiNET device
is added to an infiNET network, its MNET ID must be changed to a value that can be
addressed by the control system program (03 to 20). The MNET IDs of multiple
HTT-B10X devices on the same gateway must be unique. MNET IDs are changed
from a personal computer (PC) via Crestron Toolbox™ (refer to “Establishing
Communication” on page 16).
When setting the MNET ID, consider the following:
The MNET ID of each unit must match an ID code specified in the SIMPL
Windows or D3 Pro/SystemBuilder program.
Each network device on the same gateway must have a unique MNET ID.
For more details, refer to the Crestron Toolbox help file.
Button Installation
The HTT-B10X is shipped with 10 blank buttons (two columns of five buttons each).
To replace one or both button columns, follow this procedure:
1. Disconnect the 12 Volt power pack (if connected) and remove the batteries.
2. Remove the four Phillips screws from the four corners on the bottom of the
unit.
3. Remove the faceplate from the front of the unit.
4. Remove the old button column(s) and replace with the new one(s), making
sure the column is seated in the two small holes on the side. No screws are
required.
5. Replace the faceplate on the front of the unit.
6. Replace the four Phillips screws on the bottom of the unit.
7. Reinstall batteries and reconnect 12 Volt power pack.
8 infiNET™ TableTop Controller: HTT-B10X Operations Guide – DOC. 6583B