Chapter 2: Installation
11
However, if further receivers are connected in cascade to the initial receiver using its LINK OUT
port (Emerge EMS1000MP-R models only), then the overall length of the link cables used must
be reduced. For further information, please refer to the section Making Cascade Connections.
NOTE: Where possible, avoid laying the twisted pair link cable(s) alongside power cables.
Emerge EMS1000P models
1. Attach the connector of the link cable to the socket labeled LINK on the
Emerge EMS1000P transmitter. There should be a click when the
cable is fully inserted and locked in place.
To Connect the Link Cable(s)
The links between the transmitter and receiver units are made using between one and four twisted
pair cables, specied to Category 5 or higher. Each cable carries video and audio signals to each
receiver unit.
When a single receiver is attached to a link cable, the maximum length of that link cable is 1000
feet (600 feet for EMS1000P models).
Figure 2.7: Connecting the link cable to the
EMS1000P transmitter unit
Overall maximum link length:1000 feet (600 feet for EMS1000P)
Transmitter
Receiver
Figure 2.6: Overall maximum link length (1000 feet) when one receiver is connected