Athena Technologies C10 Satellite Radio User Manual


 
30
6 - Technical specification
Features
(at 25°C enviromental temp.)
Operating mode
and Outputs
Control Mode
OP1 output
OP2 output
AL1 alarm
(indicator with 2 alarms)
AL2 alarm
Description
1 PID loop or 1 ON-OFF
loop with 1 Alarm
Indicator with 2 alarms
Algorithm PID with overshoot control or ON OFF
Hysteresis 0.1…10,0% c.s.
Proportional band (P) 0.5…999.9%
Integral time (I) 0.1…100.0 min
Off = 0
Derivative time (D) 0.01…10.00 min
Cycle time 1…200 sec
Overshoot control 0.01…1.00
High limit 100.0…10.0%
Hysteresis 0.1…10.0%
SPST Relay N.O., 2A/250V
~
for resistive load
Triac, 1A/250V
~
for resistive load
Hysteresis 0.1…10,0% full scale
Active high
Active low
Logic, not isolated: 5V–, ± 10%, 30mA max
Absolute threshold, whole range
ON-OFF algorithm
PID algorithm
Control output
OP1 - Relay or Triac OP2 - Logic
AL2 alarm
OP2 - Logic OP1 - Relay or Triac
AL1 alarm AL2 alarm
OP1 - Relay or Triac OP2 - Logic
OP2 - Logic OP1 - Relay or Triac
Action
Active high
Active low
Action type
Deviation threshold ±range
Band threshold 0…range
Absolute threshold whole range
Special function Sensor break