Anritsu S331C Stereo System User Manual


 
SWEEP Displays the Sweep function soft key menu for the current operating mode.
Sweep Menu Provides for changing the display resolution, single or continuous sweep, and
access to the Trace Math functions.
Choosing
SWEEP in FREQ or DTF measurement modes causes the soft keys
below to be displayed.
q
RESOLUTION — Opens the display to change the resolution. Choose 130,
259, or 517 data points. (In DTF mode, resolution can be adjusted through
the DTF-AID table.)
q
SINGLE SWEEP — Toggles the sweep between single sweep and continu
-
ous sweep. In single sweep mode, each sweep must be activated by the
RUN/HOLD button.
q
TRACE MATH — Opens up the Trace Math functions (trace-memory or
trace+memory) for comparison of the real time trace in the display with any
of the traces from memory. (Not available in DTF mode.)
q
TRACE OVERLAY — Opens up the Trace Overlay functions menu to allow
the current trace to be displayed with a trace in memory overlaid on it.
Choose ON or OFF and SELECT TRACE to select the trace from memory to
be overlaid.
Choosing
SWEEP in SPECTRUM ANALYZER mode causes the soft keys below
to be displayed.
q
RBW — Sets the resolution bandwidth so that it is either coupled automati-
cally to the span (
AUTO) or manually adjustable (MANUAL).
q
VBW — Sets the video bandwidth so that it is either coupled automatically to
the span (
AUTO) or manually adjustable (MANUAL).
q
MAX HOLD — Displays and holds the maximum responses of the input sig-
nal.
q
CONT/SINGLE — Toggles between continuous and single sweep.
q
MEASURE — Activates a menu of measurement related functions. Use the
corresponding softkey to select the measurement function.
q
FIELD STRENGTH — Accesses a menu of field strength measurement
options.
ON/OFF - Turns field strength measurements on or off.
SELECT ANTENNA - Selects an antenna profile to be used for field
strength measurements.
BACK - Returns to the previous menu.
q
OBW — Activates the occupied bandwidth menu. Select either
METHOD, % or dBc method of occupied bandwidth measurement.
METHOD allows selection of either % of power or dB Down.
Selecting % allows entry of the desired % of occupied bandwidth to be
measured.
Selecting dBc allows entry of the desired power level (dBc) to be mea
-
sured.
q
DETECTION — Accesses a menu of detector modes including POSI
-
TIVE PEAK detection, AVERAGE detection and NEGATIVE PEAK
detection.
2-13
Chapter 2 Functions and Operations