Aiwa NSX-A508 CD Player User Manual


 
GEQ
SHIFT
*,”..,,.,:.!. ~ *“, g, ,:,, .,_. #j,, ,, -,.,, ~~ .4 .: L“ _ ‘,.’ ,, = ‘;=. ;- : .! _ ,.- ; ,- = i- ,--
3,EIMIIS-=4Sw cl”s %w3!?-
SELECTING
THE
PROGRAMMED
EQUALIZATION CURVE
This unit provides the following 5 different programmed
equalization curves.
ROCK: Powerful sound emphasizing treble and bass
POP: More presence in the vocals and midrange
JAZZ: Accented lower frequencies for jazz-type music
CLASSIC: Enriched sound with heavy bass and fine treble.
LATIN: JAZZ- type equalization curve with higher frequencies
Press GEQ, and turn MULTI JOG to select one of the
programmed equalization curve within 4 seconds.
GRAPHIC EQUALIZER
“GRAPHIC EQUALIZER appears (except “GEQ OFF”) and the
GEQ mode is displayed cyclically as follows.
~ ROCK+ POP -JAZZ+ CLASSIC e LATIN 1
L
~---------- Progra:med mode ----------:
GEQOFF— M4— M3— M2— Ml
J
(cancel) t
.------ Manual mode -----:
To display the current GEQ mode
Press GEQ.
The current mode is displayed for 4 seconds.
To cancel the selected mode
Press GEQ, and turn MULTI JOG to select” GEQ OFF within 4
seconds. “GRAPHIC EQUALIZER disappears.
To select with the remote control
Press GEQ repeatedly while pressing SHIFT.
The GEQ mode is
displayed cyclically as above.
To change the spectrum analyzer display
3 patterns of spectrum analyzer display can be shwon.
Press DISP once, and turn MULTI JOG within4 secondstoselect
the desired spectrum analyzer display.
SETTING A NEW EQUALIZATION CURV-E
MANUALLY
The equalization curve can be customized to suit your preference.
1
2
3
4
Press LOW.
The lowest level frequency indicator flashes for 4 seconds.
Within 4 seconds, turn MULTI JOG to adjust the
level of the lowest frequency.
Press HIGH.
The highest level frequency indicator flashes for 4 seconds.
Within 4 seconds, turn MULTI JOG to adjust the
level of the highest frequency.
The frequency level indicators of between the lowest and the
highest are adjusted accordingly.
------- :
- ---- -.”-i< *.”:- =-~V?G3.=’,..
MEMORIZlN6 ‘tHE ‘NE-W EQUALIZATlON
CURVES
Up to 4 customized equalization curves can be stored as the
manual modes Ml - M4.
1
2
3
4
Set a new equalization curve with HIGH, LOW and
MULTI JOG.
See
“SETTING A NEW EQUALIZATION CURVE MANUALLY”.
The created curve is displayed for 4 seconds.
Within 4 seconds, press ENTER.
“M 1“ flashes on the display for 4 seconds.
If this step is not completed within 4 seconds, press GEQ
first to display “GEQ ON”. Then press ENTER wtihin 4
seconds.
Within 4 seconds, turn MULTI
JOG to select one
of the manual modes Ml - M4 to store the curve.
Within 4 seconds, press ENTER.
The new equalization curve is stored.
To
select the stored equalization curve
Press GEQ, and turn MULTI JOG to select one of the manual
modes Ml - M4 within 4 seconds.
7 ENGLISH