ZETA Music Systems ZMC-200 Speaker System User Manual


 
55
ZETA Music Systems, Inc.
ZMC-200 Manual Rev2.0
Sometimes wrong notes
Description: When I play the instrument, the notes I hear are all or partly
wrong notes.
Possible problem: Discrepancy in tuning.
Solution:
1. Tune your instrument using the ZETA SYNTHONY II’s tuning
aids.
2. If you want to tune your ZETA SYNTHONY II to your instrument,
use the Tune-Base function in GLOBAL MODE.
3. It’s possible that the transpose function in the preset split is ON.
4. Turn TRANSPOSE OFF in PRESET MODE.
5. Your MIDI instrument may be set to another tuning or have its
transpose function turned ON. Check to see if these parameters are
set to the correct values.
Varying string volume levels
Description: One or more strings are not loud enough in comparison
to the others.
Possible problem: The string sensitivity of the individual strings is not set
well.
Solution:
1. In GLOBAL MODE, try resetting the sensitivity of the problematic
strings.
Dynamic difference between notes is too great
Description: With some sounds the drastic dynamic differences between
notes is irritating.
Possible problem: Setting problems in the touch sensitivity parameters.
Solution:
1. The touch sensitivity settings in your ZETA SYNTHONY II should
correspond to the sound in your MIDI instrument that you are
using.
2. Try reducing the value in the touch sensitivity parameter of the
preset split (PRESET MODE) and then try adding some value to
the Velocity Offset parameter.
Wrong sounds
Description: The sounds that appear in the ZETA SYNTHONY II’s
display do not correspond with the sounds I hear from my MIDI
instrument.