Yamaha ProR3 Stereo Amplifier User Manual


 
Advanced uses (2) – Editing functions – 25
ProR3 Digital Reverberator
Reverb + Flanger (Rev + Flg)
Key Parameter Value Description
MAIN
REV RevTime 0.3 ~ 99.0 s
Refer to “Reverberation” items on page 18
REV IniDelay 0.1 ~ 200.0 ms
REV HighRatio X0.1 ~ X1.0
REV LowRatio X0.1 ~ X2.4
REV Diffusion 0 ~ 10
FLA Mod Freq 0.05 ~ 40.00 Hz Modulation frequency of the flanger
FLA Depth 0 ~ 100% Modulation depth of flanger
FLA Delay 0.1 ~ 100.0 ms
Larger values produce modulation in the low range, and
smaller values in the high range
FLA FeedBack Gain 0 ~ 100% Feedback amount of the flanger
FINE
FLA/REV Balance *1
*1 Only when REV Patch is parallel (Reverb + Flange)
0/100 ~ 100/0 Level balance of reverb and flanger
REV Rev Mix *2
*2 Only when REV Patch is serial (Reverb Flange, Flange Reverb)
0 ~ 100% Reverb amount
REV Reverb Type *3
*3 Hall, Room, Vocal, Plate
Type of reverb tone
REV Density 0 ~ 100 Density of reverb
REV HPF Thru, 40 Hz ~ 1.0 kHz Cutoff frequency of reverb high pass filter
REV LPF 400 Hz ~ 20 kHz, Thru Cutoff frequency of reverb low pass filter
REV Space Mod 0 ~ 10 Modulation level of reverb
REV Patch *4
*4 Reverb + Flange, Flange Reverb, Reverb Flange
Connection of flanger and reverb
Common parameters Refer to “Common parameters” on page 27