TC electronic SDN BHD 48 Stereo System User Manual


 
57
Additional parameters
Bypass
Bypass function for the entire plug-in.
In/Out
In level Range : -24 to 0 dB
Out level Range : -24 to +12 dB
Sets the Input/Output levels for the algorithm. If the
Internal overload indicators “O/L” are lit, you may need to
readjust the In/Out levels.
Meters
In and output meters. For best performance the In meter
should show as close to 0 dB as possible without
clipping.
Kill Dry - Kill wet
A reverb can be used either as an insert effect or as a
send effect.
Most often it is used as a send effect on a bus. The bus
is fed from the channels you apply the effect to. When
used as a send effect the Kill Dry should be set to “on”
and this is also the default setting. When used as an
insert channel, dry signal is necessary and Kill Dry should
be set to “off”.
FABRIK R STUDIO
Routing modes
Two routing modes can be selected via the Routing mode
drop-down menu.
Plug-In mode
- must be selected when Fabrik R Studio is
used as VST plug-in.
Inter
nal mode - Use internal mode when Fabrik R is used
without a host program with VST facilities.
Example:
Using Plug-In mode in a recording situation will add a
slight delay on the reverb. The delay length is depending
on the selected Buffer Size (set on the System Settings
page). However, as the reverb is used as a send effect,
unlike Fabrik C which processes the entire signal, you will
most likely not notice that delay in a recording situation
on the Reverb. Therefore we suggest using the Plug-In
mode for Fabrik R in both recording and mixing.