9
Product overview
Overview of the displays
After switch-on, the receiver displays the “Bank/Channel” status display.
For further illustrations and examples of the different status displays,
refer to page 38.
Each display provides information on the operating states of the receiver
and those of the received transmitter.
Reception display
³ RF level display “RF” for antenna A
· Diversity display (antenna A or antenna B active)
» RF level display “RF” for antenna B
¿ Audio level display “DEV”
´ Display for the squelch threshold
Status display
² Frequency display
¶ “MHz” – appears when the frequency is displayed
º 6-step transmitter battery status display
¾ Command display (status display for the audio outputs AF and
Command)
(EM 3732 COM-II twin receiver only)
µ Display for the compander system
¸ Display for the current frequency bank and channel or the name
Brightness control
The display has an automatic brightness control. The brightness is dimmed
after the last button press. With each new button press, the display lights
up with full brightness.
300
100
30
10
10
50
100
PEAK
µV
RF
% DEV
M
H
z
776.000
01.01
BANK
CH
A B
COM
AF
HD
P
³
» ¿ ² ¶ º
¸ µ´
·
¾
For additional information, refer to page 10.
For additional information, refer to page 11.
Triggers for dimming after Behavior of the display
No operation 60 s Display is slightly dimmed
Squelch not reached 20 min Display goes off