+/– buttons to change the setting to YES. The
screen will change to a confirmation screen.
Press the ENTER button to store the new USER
DEFAULT settings. To return to the MAIN menu
without saving any changes, change all en-
tries on the screen to NO and press the EN-
TER button.
NOTE
: If there is insufficient memory to store a
USER DEFAULT configuration file, the USER
DEFAULT SET option will not be available.
To activate memorized USER DEFAULT
settings: After you have stored a USER DE-
FAULT configuration file, you can activate those
settings at any time by placing the highlight
on the USER DEFAULT line using the UP/
DOWN buttons. Use the +/– buttons to change
the setting to YES. The screen will change to
a confirmation screen. Press the ENTER but-
ton to proceed with activating the USER DE-
FAULT settings. To return to the MAIN menu
without activating the USER DEFAULT settings,
change the entry to NO and press the EN-
TER button.
ZONE 2 SETUP Menu
ZONE2 SETUP
SOURCE: CD
VOLUME SETUP: Variable
VOLUME: 20
ENT KEY=MAIN MENU UP KEY=up
+/– KEY=change DWN KEY=down
The ZONE 2 SETUP menu provides settings
and configuration options related to the op-
eration of Zone 2. This menu is reached by
highlighting the ZONE 2 line on the MAIN
menu and pressing ENTER.
SOURCE: the source selected for listening in
Zone 2. Selecting the OFF option turns Zone
2 off.
VOLUME SETUP: configures the Zone 2
outputs for VARIABLE or FIXED volume levels.
VARIABLE allows control of the volume settings
in Zone 2 from the RSP-1066 front-panel or
from a remote control/IR repeater or keypad
in Zone 2. FIXED output disables the Zone 2
volume control. In this mode, the Zone 2 level
can be fixed at the level specified on the next
line, thus optimizing system performance when
sending a fixed level signal to a preamp or
amplifier with its own volume adjustment.
VOLUME: In VARIABLE output mode, this line
shows the current volume setting for Zone 2.
In FIXED output mode, this volume setting es-
tablishes a permanent fixed output level for
Zone 2.
Move the highlight to the desired line using
the UP/DOWN buttons and use the +/– but-
tons to adjust the volume level. To return to the
MAIN menu, press the ENTER button. Press
the MENU key on the remote to cancel the
display and return to normal operation.
Specifications
Audio
Total Harmonic Distortion
<0.05%
Intermodulation Distortion (60 Hz:7 kHz)
<0.05%
Frequency Response
10 Hz - 95 kHz, ±1 dB (line level)
10 Hz - 20 kHz, ±0.3 dB (digital level)
Signal to Noise Ratio (IHF A-weighted)
95 dB (Stereo) Analog
92 dB (Dolby Digital, dts) 0dBFs
Input Sensitivity/Impedance
Line Level: 200 mV/47 kohms
Tone Controls (Bass/Treble)
±8 dB at 100 Hz/10 kHz
Preamp Output Level
1.2 V (200 mV Input)
Video
Frequency Response
3 Hz – 10 MHz, ± 3 dB
Signal to Noise Ratio
45 dB
Input Impedance
75 ohms
Output Impedance
75 ohms
Output Level
1 volt
General
Power Consumption:
40 watts
Power Requirements (AC)
115 volts, 60Hz (USA version)
230 volts, 50Hz (CE version)
Weight
7.6 Kg/16.7 lb.
Dimensions (W x H x D)
432 x 122 x 341 mm
17" x 4
7/8" x 131/2"
Front Panel Height
(feet removed/for rack mount)
109 mm/4
5/16"
All specifications are accurate at the time of
printing.
Rotel reserves the right to make improvements
without notice.
Rotel and the Rotel HiFi logo are registered
trademarks of The Rotel Co, Ltd., Tokyo, Japan.