Roland AR-200S Cassette Player User Manual


 
23
Control I/O Connector Specifications
fig.ControlB
Control Input and DC Input Terminal (CONTROL A) “1, 2” are
connected in parallel with Control I/O Connector (CONTROL B) “1, 2.”
When using Program Playback on a PC card created by the AR-3000, use
connectors 1 (INC), 3 (DEC), 5 (EXCHANGE), 9 (START), and 10 (STOP).
* Do not make any connection to NC pins, since this will cause faulty operation.
Power can be supplied to the AR-200S from an external power supply
unit (DC power supply) as well as from the AC adaptor.
To supply power from an external power supply unit (DC power), use
the Control Input and DC Input Terminal (CONTROL A) or the Control
I/O Connector (CONTROL B) DC IN and GND pins.
Power Supply Specifications
DC +9–24 V, 1200 mA
* The DC OUT pin of the Control I/O Connector (CONTROL B) can be used as
power supply for a sensor, etc.
Never short a power supply pin (21, 24, 25) to the GND pin, since this
will damage the unit.
When using the DC OUT, be careful not to exceed the maximum rating
(100 mA).
For reasons of safety, do not connect the DC IN + pin of the Control Input
and DC Input Terminal (CONTROL A) to metal parts such as the chassis
or the Control I/O Connector (CONTROL B).
Do not supply electrical power simultaneously to multiple connectors or
terminals; doing so may result in damage to the unit.
Port No.
Signal Name Remark
1
1/INC
Control Input
2 2
3 3/DEC
4 4
5 5/EXCHANGE
6 6
7 7
8 8
9 9/START
10 STOP
11 COM (GND)
12 COM (GND)
13 BUSY OUT Control Output
14 NC
15 CONT OUT Control Output
16 GND
17 BUSY OUT
Control Output
18 CONT OUT
19 NC
20 NC
21 DC OUT +5V, Max: 100 mA
22 GND
23 GND
24 DC IN
+9–24V, 1200mA
25 DC IN
13 1
25 14
DC Power Supply
AR-200S_e.book 23 ページ 2005年12月8日 木曜日 午前9時3分