NEC N8800-099F Speaker System User Manual


 
6-12 Troubleshooting
6. Reinstall GeminiEngine Control Software.
Reinstall GeminiEngine Control Software referring to “Installing GeminiEngine Control
Software” (page 6-13).
7. Check disk mirroring.
If the disk mirroring is disabled, enable the mirroring again. For the method to check disk
mirroring, see “Step 6: Set Dual Disk Configuration.”
IMPORTANT:
During disk re-synchronization, do not shut down the system until the resynchronization
is completed.
If the following dialog appears, confirm that the disk is mirrored and click [Yes] to restart
the system.
8. Reboot the system.
9. After the system has rebooted, log on as a user with Administrative account.
IMPORTANT:
Check that the dual system is configured properly (confirm that the FT STATUS LED on
the front panel of the server illuminates green. See page 4-7 for location of the STATUS
LED).
10. Duplicate the LAN again for both onboard and option boards.
Refer to “Step 5: Set Dual LAN Configuration” on page 4-23 or “DUAL LAN
CONFIGURATION” in Chapter 3 of the separate volume of User’s Guide. Reconfigure the LAN
based on the memo you have taken.
11. When it is necessary for the system operation, enable [Boot Monitoring] selected in [Monitoring
Configuration] of [Server]. See “Step 11: Enable Boot Monitoring Function” on page 4-35 for
details.