Chapter 1 Introduction
©
National Instruments Corporation 1-3 VXI-SC-1102/B/C User Manual
The VXI-SC-1102/B/C submodules operate with full functionality with
National Instruments VXI-MIO modules. You can multiplex several
VXI-SC-1102/B/C submodules and other VXI signal conditioning
submodules into a single channel on the VXI-MIO module, greatly
increasing the number of analog input signals that you can digitize.
You can also use National Instruments terminal blocks, which have
screw terminals to which you attach the input signals for the
VXI-SC-1102/B/C submodules. In addition, some of these terminal
blocks have a temperature sensor for thermocouple cold-junction
compensation (CJC). The VXI-SC-1102/B/C submodules multiplex
this cold-junction sensor with the 32 input channels during a hardware
scan. A National Instruments isothermal terminal block is
recommended for thermocouple applications.
Detailed specifications of the VXI-SC-1102/B/C submodules are listed
in Appendix A, Specifications.
What You Need to Get Started
To set up and use your VXI-SC-1102/B/C, you will need the following
items:
❑ One of the following submodules:
VXI-SC-1102
VXI-SC-1102B
VXI-SC-1102C
❑ VXI-SC-1102/B/C User Manual
❑ VXI-SC-1000 carrier module and documentation
❑ VXI-MIO module and documentation
❑ One of the following software packages and documentation:
ComponentWorks
LabVIEW for Windows
LabWindows/CVI for Windows
Measure
NI-DAQ for PC compatibles
VirtualBench
VXIplug&play instrument driver
❑ Your VXIbus system