13
ENGLISH
• If or flashes, the digital data is not being received
correctly. Check all connections and settings on both the
source unit and the CDR500.
55
55
5
Set the optimal recording level on the CD-Recorder.
1. Play the source first to set the optimal recording level on
the CD-Recorder.
2. Rotate the
REC LEVEL/SELCT
(13) key until, on the
Record/Play Level bar, all the blue segments light but
the red segments do not light continuously during the
loudest passages.
DIGITAL RECORDING : +6dB ~ –63dB
ANALOG RECORDING: 0dB ~ –63dB
3. Stop the source.
• To record a 3-second silence at the start of a track,
press 2/; (6) or ; (82) before starting the source.
66
66
6
To start recording, press
00
00
0 (4) on the CD-Recorder and
immediately start the source.
The track number and recording time left appear on the display.
• If 9 (5, 87) is pressed within 3 seconds after 0 (4), no
recording will take place.
• To check the elapsed recording time, press
TIME
(14) or
DISPLAY
(77). (This can also be done during
the recording.)
77
77
7
To stop recording, press
99
99
9 (5, 87).
• To pause recording, press 2/;
(6) or ; (82).
After recording, the display will show for sev-
eral seconds as it finishes recording.
Note:
The recorded sound might be distorted when you adjust the
recording level above 0dB for digital recording and -12dB for
analog recording. The default setting of record level for digital is
0dB and analog is -12dB.
Important:
If you want to play the recorded CD-R/RW disc on any
regular CD player, it must first be finalized. See finalizing
discs on page 15.
Finalized CD-RW discs play only on CD-RW compatible CD
players.
RECORDING
Manual start recording
About AUTO TRACK and AUTO STOP
• AUTO TRACK is a function to increment track numbers
either manually or automatically.
AUTO TRACK ON : track numbers will be automati-
cally incremented according to
the source. (See the table on
page 23)
AUTO TRACK OFF:
track numbers are manually
incremented by pressing
TRACK
INCR
. (73).
• When AUTO TRACK is ON, you can also set the AUTO
STOP function.
AUTO STOP ON : the recording will be stopped auto-
matically. (See the Table on page
23.)
AUTO STOP OFF: the recording has to be stopped
manually.
11
11
1
Make sure the disc is absolutely free of scratches and
dust particles.
22
22
2
Connect the CDR500 to an external source. (see IN-
STALLATION page 5 and 6.)
33
33
3
Press
INPUT
(9) repeatedly until the selected external
source appears on the display (depending on the connec-
tion used):
➔ , or lights up and ,
or appears on the display.
44
44
4
With the recorder stopped, press
REC MODE
(10) five
times to enter the Manual Record standby mode.
➔ .
The numbers between parentheses refer to the fold-out.
MENU/
STORE
CANCEL/
DELETE
0
987
654
CD
CDR
JKL MN OPQ
RST UVW XYZ
DISPLAY
SPACE
SCROLL
FUNCTION
ENTER
HEADPHONE
CD RECORDER/CD PLAYER CDR500
PROG
FINAL
TEXT
LEVEL
TIME
CDPLAY MODECDR
INPUT
ERASE
MENUREC.M
POWER
IR
STANDBY
010
PUSH ENTER
REC LEVEL/SELECT
DELETE
STORE
CANCL
Recordable
ReWritable
u