k. Advanced set-up
The sub menus accessible in the Display menu are:
Master/Slave
Line Out Volume
Software version
Default
As default a TDA 2200 is set as a Slave. The Master setting should be used if you are
using two TDA 2200, e.g. for bi-amping or if using one to drive the main loudspeakers and
one to drive the (sub)woofer(s). When set as a Master the first TDA will control the second
TDA (the Slave) e.g. when adjusting the volume control and when switching on and off.
The Line Out level can be set as Full Scale (fixed) or regulated.
Fixed means there’s a constant full scale output – also often referred to as “tape out” since
this is most often used for this purpose.
Regulated means that the output level will follow the level of the volume control. This
setting is chosen if you have, for instance, a power amplifier or an active subwoofer
connected. If Full Scale is used in this scenario you will constantly have full output – with
huge potential for overloading and damaging the connected power amplifier and/or
loudspeakers.
The Software version menu is used to check the current software version of your TDA2200
and the RoomPerfect™ module as well as the RoomPerfect™ serial number.
The Default setting is used to restore all settings in the TDA2200 to the factory settings.
If you return to the factory settings all your personal settings will be erased.