13
7532 Mounting
3.3 Installation Conditions
3.3.1 Dimensions
Figure 4: Dimensions 7532 RTG
Note!
The inactive length of 60 mm prevents condensation effects to the antenna perfor-
mance. Special versions with longer construction are available.
Antenna version DN150 / 6" DN200 / 8" DN250 / 10" DN300 / 12"
L [mm] 93 337 490 517
Ø D [mm] no horn 190 240 290
ENDRESS+HAUSER
Micropilot II
65 (2.56")
Ø 129 (5.08")
Ø 150 (5.91")
Ø D
68 (2.68") 94 (3.7")
30
(1.18")
L
238 (9.37")
93 (3.66")
60
(2.36")
8 (0.31")
85 (3.35")
DIN, ANSI,
JIS
9
(0.35")
Ø 62,5 (2.46")
Ø 78 (3.07")
Ø 99,5 (3.92")
DN200…300 / 8…12”
version with
antenna widening
E+H UNI flange
(max.1 bar)
flange hub
mounting:
4 bolts M6 / 90°
e.g.DIN 912
O-Ring 85.3 x 3.53,
included
(same material as
sensor seal)
DN150 / 6”
version without widening
detail A:
flange adapter
(see under)
detail A
flange hub for the connection
to flanges provided by the customer
inactive length
L00-FMR532xx-06-00-00-en-001