Fluke 45 Turntable User Manual


 
Applications
Using the Dual Display
4
4-3
Table 4-1. Sample Dual Display Applications
Primary Display Secondary Display Applications
Volts DC Volts AC Monitor dc level and ac ripple of power supply
Troubleshoot amplifier circuits
Volts DC Current DC Check power supply load regulation
Monitor UUT current draw and circuit voltages
Monitor loop current and voltage drop across
transmitter
Volts DC Current AC Line and load regulation tests
dc/ac or ac/dc converters
Volts AC Current DC Line and load regulation tests
dc/ac or ac/dc converters
Volts AC Current AC Line and load regulation tests
Transformer (magnetic circuit) saturation
Volts AC Frequency Measure ac amplitude and frequency for line
voltage and ac signal analysis
Measure frequency response of an amplifier
Adjust ac motor control
Read noise in telecommunication applications
Adjust portable power generator to optimize
power output
Set frequency compensation for a network
dB (in Volts dc) Frequency Use in "print-only" mode (see "RS-232 Print-
Only Mode" in Chapter 5) for quick Bode plots
(frequency vs. amplitude)
Test frequency response
Current DC Current AC Measure ripple and dc current draw of switching
power supply
Measure current dissipation in protective fuse
resistors used in power supplies
Measure ripple and noise on a line
MN MX Actual Value Show the minimum or maximum value recorded
and the present measurement
REL Actual Value Show actual measurement and the difference
between this value and the relative base.
REL Resistance Select and sort resistors. (See also "Using the
Compare Function" in Chapter 3.)
HOLD Actual Value Show actual measurement while holding a
previous, stable measurement on the primary
display