Quick Start Guide: Connect-Power-Configure
9. Set up Sync Count to Lock/Sync Miss Sample Size
10. Set up Sync Miss Limit.
A description of each of these User Settings can be found in the Reference Guide.
Note: If the unit has successfully locked to the incoming feed, then the TS Lock
value in menu Input should be LOCKED.
3.4 Selecting a Decode Service (Program)
To select a decode service:
1. Navigate to the Service menu. For incoming feeds containing only a single
service the service may be selected automatically depending on service
selection control.
2. If the service is NOT selected, press Edit and, using the S (Up) and T (Down)
pushbuttons in the decode service sub-menu, scroll through the service name
list.
3. Press Save to select the required service.
Note: If the unit has successfully selected a service, then the Service ID and
Service name should be displayed in the Service menu.
3.5 Configuring the Video Output
When configuring the Video Output, the following points should be observed:
• The unit will automatically decode the first video component that it finds within
the selected service.
• An alternative video component may be selected from the service tab on the
Web Control interface.
• If the incoming video is successfully decoded then the status OK should be
displayed on the appropriate page.
• Successfully decoded High Definition video will be output from the connector
marked Video Component.
• Successfully decoded Standard Definition video will be output from the
connector marked CVBS.
3.6 Configuring the Audio Outputs
When configuring the Audio Outputs the following points should be observed:
EN/LZT 790 0009 R1A 2011-03-30
15 (44)