Emerson 2400S Satellite Radio User Manual


 
Installation Manual 39
Dimensions and Specifications
Return Policy IndexSpecifications
A.9 Environmental limits
A.10 Environmental effects
A.11 Hazardous area classifications
Ambient temperature limits Operating and storage: –40 to +140 °F (–40 to +60 °C)
Below –4 °F (–20 °C), LCD responsiveness decreases and LCD may become
difficult to read. Above 131 °F (55 °C), some darkening of the LCD panel might
occur.
ATEX requires limiting ambient temperature to below 131 °F (55 °C).
Humidity limits 5 to 95% relative humidity, non-condensing at 140 °F (60 °C)
Vibration limits Meets IEC68.2.6, endurance sweep, 5 to 2000 Hz, 50 sweep cycles at 1.0 g
All models
EMI effects Meets EMC directive 89/336/EEC per EN 61326 Industrial
Conforms to NAMUR NE21 Version: 10.02.2004
Model 2400S Analog only
Ambient temperature effect On mA output: ±0.005% of span per °C
All models
CSA
(1)
C-US
(1) CSA is a Canadian approvals agency that provides approvals accepted both in the U.S.A. and in Canada.
Class I Division 2 Groups A, B, C, D
Class II Division 2 Groups F and G
ATEX
(2)
(2) ATEX is a European directive.
Zone 1 Analog II 2GD EEx mb e ib IIC T4
Zone 2 Analog or
PROFIBUS-DP
II 3G EEx n A C II T5
II 3D IP66/IP67 T70°C
Zone 2 DeviceNet II 3G Ex nA II T5
II 3D IP66/IP67 T70°C